Fol-Da-Tank

Multifunctional Helicopter Tank

Multifunctional Helicopter Tank

The “Flyer” Multifunctional Helicopter Water Tank

Applications

  • Filling back pack tanks
  • Potable water
  • Foam retardants
  • Extinguishing duff embers
  • Small/light pumps
  • Gravity feed reservoirs
  • Potable water fabric is available (Part No. FDA72/FDA134)

 

$845.00$2,804.00

  • Pyramid shape blivets
  • Heavy-duty vinyl 
  • Transportable by helicopter or truck
  • Heavy-duty harness
  • Kevlar thread
  • Sling harness webbing 
  • Potable water tanks available
Part No. 72F 134F
Volume US gal/liters

72/270

134/510

Filled Dimensions  in/mm

45”x39”/1140×1000

53”x43”/1350×1100

Folded Dimensions in/mm

21”x20”x8”/530x510x200

19”x26”x4.5”/480x660x120

Discharge

1” hose w/ .75” spigot

1” hose w/ .75” spigot

Filler

4” Diameter

4” Diameter

Weight lb/kg

12/5

14/8

 

 

  • Tank bladder constructed from heavy duty industrial polymer
  • The webbed harness is made from a durable nylon webbing and a forged cargo ring is attached with Kevlar thread
  • 4″ fill port
  • 1.5″ ball valve
  • NSF approved potable water fabric is available
  • 525 and 600 gallon also available
Shown filled with water. Shown without water. Air pressure testing.
Part No. FLY200 FLY300
Volume US gal/liters

240/900

360/1360

Filled Dimensions  in/mm

27”x29”x8”/680x740x200

30“x32”x12”/760x810x280

Discharge

1.5“ Ball Valve

1.5“ Ball Valve

Filler

4” Diameter

4” Diameter

Weight lb/kg

25/12

35/16

Filled Weight lb/kg

2030/919

3100/1400

 

 

Inspection of Fol-Da-Tank “Flyers”

  1. Before/After each flight use: Inspect all heat sealed seams for any tears.
  2. Inspect all stitching of the harness for any loose stitching.
  3. Inspect the dropped forged aluminum choker delta rings.   (Rated at 40,000 lbs.)
  4. Inspect the dropped forged “D” rings (rated at 5,000 lbs. each) or grab handles placed on the side of the tank bladder.
  5. Inspect the 4” fill cap on top of the tank. (or a PVC flange if requested on the tank)
  6. The flyer tank should be stress tested regularly by hanging the bladder from an engine hoist that is rated for the water weight, or a helicopter can raise the tank for aerial inspection.
  7. Consider replacing the Flyer tank after 3-4 years of use.  This is if the tank has be use often.
  8. Warranty is for 2 (two) years from purchase date.  Warranty includes: all heat sealed seams, and fabric UV delamination.  We only use the best quality fabrics and parts for this type of tank!!
  9. Emergency patch kits are available.
  10. Always store flyer tanks indoors in a clean dry area free of rodents and pests.
  11. For 72 & 134 gallon flyers: Inspect all hose and connection outlets.

*Always refer to the Helicopter Load Calculation and Manifest section of the Interagency Helicopter Operations Guide.

CAUTION!  If the tank has been subjected to fire, immediate inspection is required!!

Testing of 72, 134, 200 & 300 gallon flyers before shipping to customer:

  1. When cutting the fabric all fabric is inspected for imperfections
  2. After the bladder is completed we inspect all heat sealed seams.
  3. Inspection of webbing and hardware is done before assembly.
  4. After completion of the bladder we air pressure test for any leaks
  5. Hydro testing of bladders is done to see if there is any leaking.
  6. The bladder is now cleaned and dried for shipment.
  7. At each stage employees must initial their part of the assembly before shipping.
  8. Maintenance, cleaning and warranty instructions are included with every tank.